Selection
- Map each sensor to the correct bearing, gearbox or generator channel before wiring.
- Confirm power budget, Keyphasor allocation, network addresses and data ownership with the control system.
A DIN-rail condition-monitoring platform for wind-turbine generator trains, with 12 dynamic inputs, dual Keyphasor channels and Ethernet connectivity.
Item NO.:
60M100-00Order(MOQ):
1Goods Stock:
12Payment:
T/TLead Time:
In stockWeight:
1.48kgDimension:
24.5x15.5x6.2cmDescription:
60M100 Condition Monitoring SystemPrice:
AskA DIN-rail condition-monitoring platform for wind-turbine generator trains, with 12 dynamic inputs, dual Keyphasor channels and Ethernet connectivity.
Designed for continuous wind-turbine condition monitoring, the 60M100 brings vibration, speed reference and process context together in one compact DIN-rail unit. It can manage the main bearing, gearbox and generator measurement set without turning the cabinet into a collection of isolated devices. That integrated monitoring role is the central value of 60M100-00 in a wind-turbine maintenance program.
Up to 12 dynamic inputs and two Keyphasor signals feed a 24-bit acquisition path with bandwidth to 40 kHz. Independent Ethernet ports support plant and service connectivity, while buffered outputs and front-panel status indicators help commissioning and field diagnosis. The acquisition and network resources of 60M100-00 support both commissioning checks and ongoing diagnostics.
A successful installation starts with channel assignment, sensor power and network planning. Verify the 18-36 Vdc supply, configure the correct asset and alarm modes, then retain baseline spectra, waveforms and operating state for future maintenance decisions. A documented 60M100-00 configuration gives later analysts the context needed to interpret changing spectra.
Build the channel map from the turbine asset model: main bearing, gearbox stages and generator bearings. Keep sensor type, orientation and measurement purpose with each channel record.
Verify sensor gap, pulse polarity, threshold, cable continuity and the selected Keyphasor input before changing speed-dependent analysis settings.
Ethernet link status only proves the connection. Check sensor power, channel configuration, asset mapping, time alignment and operating mode for the actual measurement path.
Collect stable data across the normal generator power modes, confirm sensor quality and machine state, then set alert and danger levels from the approved monitoring strategy.
Check the 18-36 Vdc supply, input wiring and module configuration. Use the individual channel and network indicators to narrow the fault before replacing hardware.
Save the channel map, sensor list, network settings, Keyphasor setup, baseline spectra and waveforms, alarm settings and turbine operating mode.
Products supplied by ApterPLC are covered for 12 months under the applicable sales terms. Keep the complete unit nameplate and transaction record so the exact product can be identified during technical support.
The attached selection contains the official description, performance data, environmental limits, ordering codes and product drawings relevant to 60M100-00. Unrelated catalog pages have been removed.
|
330104-06-12-10-02-00 |
330130-035-00-00 |
330130-040-02-00 |
|
330104-06-14-50-02-00 |
330130-035-00-CN |
330130-045-00-00 |
|
330104-10-18-10-01-00 |
330130-030-01-CN |
330130-045-00-05 |
|
330104-10-20-05-02-00 |
330106-00-04-10-02-00 |
330130-040-00-00 |
|
330104-10-20-10-02-05 |
330106-05-30-05-02-00 |
330130-040-00-05 |
|
330104-12-20-10-01-00 |
330105-02-12-50-02-00 |
330130-040-01-05 |
|
330104-13-20-10-02-00 |
330106-05-30-10-02-00 |
330130-045-01-00 |
|
330104-15-23-10-02-00 |
330106-05-30-10-02-05 |
330130-045-02-05 |
|
330104-19-25-10-11-05 |
330106-05-30-15-02-00 |
330130-045-03-05 |
|
330105-02-12-05-02-00 |
330106-05-30-50-02-00 |
330130-035-01-CN |
|
330105-02-12-05-02-05 |
330130-00-05-05-02-00 |
330130-045-00-CN |
|
330105-02-12-10-02-00 |
330106-05-30-05-02-CN |
330130-045-01-CN |
|
330105-02-12-15-12-05 |
330106-05-30-10-02-CN |
330130-040-00-CN |
|
330105-02-12-15-12-CN |
330106-05-30-15-02-CN |
330130-040-02-CN |
|
330105-02-12-05-02-CN |
330106-05-30-20-02-CN |
330130-040-10-CN |
Related Tags :