Mounting geometry
- Confirm bracket clearance for the 250 mm case.
- Set insertion depth from the machine drawing and required gap, not from the 120 mm code alone.
- Compare the complete order code before replacing another M10 × 1 probe.
Item NO.:
330103-12-25-10-01-00Order(MOQ):
1Goods Stock:
15Payment:
T/TLead Time:
In stockWeight:
1.3KGDimension:
7.6x5.1x35.6cmDescription:
PROBEPrice:
AskAn unarmored M10 × 1 probe with a 120 mm unthreaded section, 250 mm case, 1.0 m total length, protected ClickLoc connection and the no-approval option.
For a long-body mounting position, 330103-12-25-10-01-00 provides an unarmored M10 × 1 probe with a 120 mm unthreaded section and a 250 mm overall case.
A documented 1.0 m channel uses 330103-12-25-10-01-00 directly with the matching 1.0 m Proximitor Sensor, without an extension cable in the measurement chain.
Environmental planning for 330103-12-25-10-01-00 benefits from its option-01 protector over the miniature coaxial ClickLoc connection, while the ending 00 identifies a configuration without agency approvals.
The 120 mm value describes only the unthreaded case section; it is not an insertion-depth or gap setting. The machine drawing, bracket position and target location establish the installed depth and operating gap.
The shared geometry and 1.0 m length do not make the order codes identical. Option 01 includes a connector protector while option 02 does not, so the replacement choice depends on the environmental protection required at the ClickLoc joint.
The ClickLoc joint is correctly seated when the two gold connectors are finger-tight and have clicked; no installation tool is needed. The option-01 protector can then be returned over the seated joint.
Movement-sensitive output points first to the cable route or connection. The 25.4 mm bend radius, absence of pull or abrasion, ClickLoc seating and physical gap help distinguish a lead or connection issue from a sensing-tip fault.
The protector improves environmental protection but does not change approval status. The ending 00 is the no-approval selection, so a certified location needs a configuration carrying the required approvals.
This probe should not be used as the sole pressure-containment basis. Bently Nevada does not pressure-test 3300 XL 8 mm probes before shipment, so a service that depends on pressure sealing requires a separately specified and completed pressure test before startup.
The supplied product is covered for 12 months under ApterPLC's sales terms. Keep the product nameplate, original packaging and transaction record available if warranty support is required.
|
330130-080-03-05 |
1701/15 |
330103-12-25-10-01-00 |
|
330130-080-02-00 |
128031-01C |
330103-12-25-10-02-00 |
|
330130-040-10-CN |
VELOMITOR 330500 |
330103-13-23-05-02-00 |
|
330103-00-08-10-02-05 |
130944-01 128275-01F |
330104-00-02-10-02-00 |
|
330104-00-25-10-02-00 |
330103-11-19-10-02-00 |
330104-00-04-05-02-00 |
|
330104-00-20-05-02-00 |
330103-05-10-10-02-05 |
330104-00-04-10-02-00 |
|
330104-00-22-10-02-00 |
330103-05-12-10-01-00 |
330104-00-04-10-02-05 |
|
330104-00-12-05-02-00 |
330103-05-13-10-02-00 |
330104-00-04-50-11-00 |
|
330104-10-20-05-02-00 |
330103-05-15-05-02-00 |
330104-00-05-05-02-00 |
|
330905-00-07-10-02-00 |
330103-06-13-10-02-00 |
330104-00-05-10-02-00 |
|
330172-16-42-10-01-00 |
330103-07-12-10-02-00 |
330104-00-05-50-02-00 |
|
330101-02-78-05-02-00 |
330103-07-16-05-02-00 |
330104-00-06-05-02-00 |
|
330104-00-15-10-01-CN |
330104-00-08-10-02-CN |
330104-00-06-10-02-00 |
|
330103-00-21-10-11-CN |
330103-06-13-05-02-CN |
330104-00-04-10-02-CN |
|
330703-000-050-10-02-00 |
330710-000-060-10-02-00 |
330103-15-23-05-02-CN |
Related Tags :