Item NO.:
330103-00-03-05-02-00Order(MOQ):
1Goods Stock:
29Payment:
T/TLead Time:
In stockWeight:
0.04KGDimension:
57x1.8x1.5cmDescription:
PROXIMITY PROBESPrice:
Ask3300 XL 8 mm proximity transducer system · M10 × 1 · standard cable
Manager JimPei · Nameplate, mounting and system-length review for maintenance and project purchases.
330103-00-03-05-02-00 is a metric 3300 XL 8 mm forward-mount probe with an M10 × 1 thread, zero unthreaded length, a 30 mm overall case and a 0.5 m standard integral cable. It uses the miniature coaxial ClickLoc connector without the separate protector option.
330103-00-03-05-02-00 is intended for metric mounting hardware and carries the 00 approval selection. The short probe lead must be completed with a manufacturer extension cable and matching Proximitor Sensor, while the mounting thread, case reach and route protection must match the machine drawing.
Separates this configured probe from visually similar 3/8-24 UNF versions.
Zero unthreaded length and a 30 mm case define the available mounting reach.
The short integral cable leaves 4.5 m or 8.5 m to be completed for common system lengths.
The two thread forms can look similar but are not interchangeable. Confirm the bracket or machine-thread callout and use the matching metric locknuts before installation; stop immediately if engagement feels tight or uneven.
| Manufacturer | Bently Nevada, a Baker Hughes business |
|---|---|
| Product family | 3300 XL 8 mm |
| Product type | Metric forward-mount proximity probe |
| Thread | M10 × 1 |
| Cable armor | Not included |
| Unthreaded length | 0 mm |
| Overall case length | 30 mm |
| Integral cable length | 0.5 m |
| Connector / cable | Miniature coaxial ClickLoc / standard cable |
| Connector protector | Not selected |
| Agency option | 00 — not required |
| Place of shipment | Xiamen, China |
| Delivery Time | 1-3 days |
| Quantity | 100% New Original |
| Minimum Order Quantity | 1pc |
Commercial packed weight and packed dimensions remain in the page logistics fields unless the manufacturer publishes model-specific packing data.
Use the metric mounting drawing and keep thread engagement within the manufacturer limit. Set the probe gap only after confirming that the 30 mm case provides enough adjustment through the installed bracket.
For a 5 m or 9 m transducer system, the 0.5 m integral cable must be paired with the corresponding official extension-cable length and Proximitor Sensor.
No. This probe uses M10 × 1 threads. Use the correct metric mounting hardware or select the official 3/8-24 probe; stop if the installed thread cannot be positively identified.
Add the manufacturer extension cable that produces the exact total required by the matching Proximitor Sensor—typically 4.5 m for a 5 m chain or 8.5 m for a 9 m chain. Do not splice the probe lead.
Measure the bracket thickness, available M10 × 1 engagement, locknut stack and distance to the target. If the 30 mm case cannot provide safe adjustment without binding, choose the correct longer geometry before commissioning.
Check the ClickLoc seating, cable stress, total system length, probe gap and target surface in that order. Remove the physical fault before changing channel configuration or scaling.
Not from family membership alone. This code carries the 00 approval selection, so procurement must compare the project certification requirement with an officially approved configuration before ordering.
Send the full code and label photograph, M10 × 1 mounting drawing, bracket dimensions, total system length, Proximitor number, environmental conditions, quantity and destination.
Apter provides a 1-year warranty on every item we sell.
Our free 1-year warranty makes every Apter purchase a dependable, reliable investment in your company's future.
Apter sells industrial automation parts, including new and discontinued products, and purchases these products through independent channels. Apter is not an authorized distributor, dealer or representative of the manufacturers shown on this site. Product names, images, trademarks, brands and logos belong to their respective owners and are used only for identification; their use does not imply affiliation or authorization.
The existing page provides email access to the required datasheet. No unverified external download has been added.
Send the complete model, full nameplate photograph and installed-system details so the applicable manufacturer document can be checked before supply.
Related Tags :