other
Products
330400-02-00 Accelerometer Acceleration Transducer
330400-02-00 Accelerometer Acceleration Transducer
330400-02-00 Accelerometer Acceleration Transducer

Bently Nevada 330400-02-00 Accelerometer Acceleration Transducer

sA 100 mV/g casing accelerometer with an M8 x 1 integral stud for high-frequency machine monitoring.
  • Item NO.:

    330400-02-00
  • Order(MOQ):

    1
  • Goods Stock:

    24
  • Payment:

    T/T
  • Lead Time:

    In stock
  • Weight:

    0.1KG
  • Dimension:

    6.3x2.5x2.3cm
  • Description:

    ACCELEROMETER
  • Price:

    Ask

Fast, accurate industrial sourcing - share the model, quantity and delivery country.

Machinery monitoring supply

330400-02-00 - Accelerometer Acceleration Transducer

A 100 mV/g casing accelerometer with an M8 x 1 integral stud for high-frequency machine monitoring.

01

Product Overview

Bently Nevada 330400-02-00 is an acceleration transducer for casing vibration and high-frequency machine condition monitoring. Its 100 mV/g sensitivity and 50 g peak measurement range support gear-mesh monitoring and general machinery diagnostics.

The -02 mounting option provides an M8 x 1 integral stud, while -00 is the ordering choice without optional agency approvals. Buyers can therefore identify the required mounting interface and approval level directly from the full model code.

02

Key Features & Compatibility

100 mV/g output

A widely used sensitivity supports straightforward matching with compatible monitoring and signal-conditioning channels.

M8 x 1 mounting

The metric integral stud suits machine points prepared for the specified thread and keeps the mounting decision clear.

Defined approval option

The -00 suffix separates this version from the -05 configuration offered with CSA, ATEX and IECEx approvals.

03

Model Clarification & Ordering Tips

A clear 330400-02-00 label photo, required quantity, delivery country and receiving channel details help ApterPLC prepare an accurate quotation quickly. For certified-area projects, sharing the required approval standard also makes it easier to compare the -00 and -05 ordering options.

ApterPLC machinery monitoring supply support
04

Technical Specifications

Product family 330400 accelerometer acceleration transducer
Sensitivity 100 mV/g (10.2 mV/m/s2), +/-5%
Acceleration range 50 g peak
Frequency response 10 Hz to 15 kHz, +/-3 dB
Mounting thread option M8 x 1 integral stud
Agency approval option 00 - none / not required
Operating and storage temperature -55°C to +121°C
Environmental protection Hermetically sealed; equivalent to IP68 as specified by the manufacturer
Place of shipment Xiamen, China
Delivery Time 1-3 days
Quantity 100% New Original
Minimum Order Quantity 1pc
05

Compatibility & Application Notes

Channel scaling

A 100 mV/g input expectation is central to preserving meaningful vibration trends after replacement.

Mounting quality

A clean, flat mounting surface and the correct M8 x 1 interface help the transducer deliver repeatable casing measurements.

06

Applications & Use Cases

Commonly considered for casing acceleration measurement on turbines, compressors, gearboxes, motors and other rotating equipment where higher-frequency vibration information supports fault diagnosis.

07

Frequently Asked Questions

Will 330400-02-00 fit an M8 x 1 casing mounting point?

Yes. The -02 option specifies an M8 x 1 integral stud, so it suits a correctly prepared metric mounting point.

Can a 100 mV/g channel use 330400-02-00 without changing its scale?

Its published sensitivity is 100 mV/g. A matching monitor input can retain the intended scaling when the rest of the channel configuration is unchanged.

Is 330400-02-00 the right version when CSA, ATEX or IECEx approval is required?

The -00 selection is the ordering option without optional agency approvals. For projects requiring CSA, ATEX or IECEx coverage, the -05 version is normally the relevant choice, and ApterPLC can help compare the site requirement.

Could 330400-02-00 be selected as a replacement for a 330425 accelerometer?

The families have different sensitivity and acceleration range. Comparing the receiving channel first helps prevent a scale mismatch.

When does the mounting base matter for 330400-02-00?

For units with serial numbers not preceded by G, Bently Nevada recommends the mounting base to reduce base-strain sensitivity.

Does 330400-02-00 support casing measurements used in gear-mesh monitoring?

Yes. Its published response reaches 15 kHz, supporting casing acceleration work where higher-frequency vibration information is valuable.

08

Why Buyers Choose ApterPLC

Precise model supportClear model comparison helps reduce ordering risk and avoid preventable delays.

New original supplyCurrent, discontinued and hard-to-find automation parts for planned maintenance.

Responsive coordinationFast quotation, delivery support and practical post-purchase communication.

09

Alternative Names

Manufacturer-recognized family names used in catalogs and service records.

  • 330400 Accelerometer Acceleration Transducer
  • 330400 M8 x 1 Accelerometer
1 Year
Warranty
Apter purchase protection

Dependable support from order to delivery

Apter provides a 1-year warranty on every item we sell. Our team remains available for delivery coordination, receipt questions and after-sales communication.

Apter independently supplies industrial automation parts, including current and discontinued products. Product names, images and trademarks help customers identify the items they need and remain the property of their respective owners. Apter is not an authorized distributor or representative of those manufacturers.

Technical information for 330400-02-00

The official Baker Hughes document below brings together the product role, technical specifications, selection context and relevant drawings for engineering and procurement review.

Need another revision, user manual or wiring document? Share the product label and tell us which file would help your project. Our team will assist with the most relevant available document.

Baker Hughes 330400 and 330425 Accelerometer Datasheet 141638View the 330400-02-00 PDF

330980-50-00

330780-50-00

330705-02-18-10-02-00

330980-50-05

330780-90-00

330705-02-18-90-02-00

330980-51-05

330780-91-00

330703-000-040-10-02-00

330980-71-CN

330850-50-00

330703-000-040-10-11-00

330930-045-00-05

330850-50-05

330703-000-050-10-02-05

330930-045-01-00

330850-90-05

330703-000-060-10-02-00

330930-060-00-00

330730-040-03-00

330703-000-060-10-02-00

330930-040-01-00

330730-080-00-00

330703-000-060-50-12-00

330930-065-00-05

330730-080-01-00

330703-000-070-10-02-00

330930-065-01-05

330730-080-12-00

330703-050-120-10-02-00

330930-065-01-05

330730-040-00-00

330704-000-050-10-02-00

330930-065-03-05

330730-040-00-00

330709-000-040-50-02-00

330930-060-01-CN

330730-040-00-05

330709-000-070-10-02-00

33104-00-10-10-02-05

330730-080-12-CN

330709-000-070-10-02-00

3500/05-01-01-00-00-00

330851-02-000-030-10-00-05

330703-000-060-10-02-CN


Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
Categories

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

contact

whatsapp