Reverse-mount mechanics
- Confirm access from the rear side of the bracket or housing.
- Check thread engagement, retention and withdrawal clearance.
- Use the reverse-mount drawing rather than treating 02-12 as freely selectable dimensions.
Item NO.:
330105-02-12-90-02-05Order(MOQ):
1Goods Stock:
16Payment:
T/TLead Time:
In stockWeight:
0.1KGDimension:
2.2x12.4x12.6cmDescription:
PROXIMITY TRANSDUCERPrice:
AskA 3/8-24 UNF reverse-mount 3300 XL 8 mm probe with fixed 02-12 geometry, 9.0 m total length, standard ClickLoc connection and CSA/ATEX/IECEx option.
Rear-side installation access is central to 330105-02-12-90-02-05 because its 3/8-24 UNF reverse-mount body uses fixed 02-12 geometry, with a 5 mm unthreaded section and a 30 mm case.
For classified-area planning, 330105-02-12-90-02-05 carries CSA, ATEX and IECEx option 05, while its option-02 ClickLoc connection is supplied without a factory-installed protector.
The integral 9.0 m lead on 330105-02-12-90-02-05 reaches the matching 9 m Proximitor Sensor directly, so rear withdrawal clearance and lead routing are arranged without an extension cable.
The reverse-mount arrangement needs rear-side room for insertion and retention, suitable thread engagement, withdrawal clearance and a route for the 9.0 m integral lead that does not load the probe case.
The 02-12 portion is a fixed reverse-mount format rather than two freely selectable dimensions. Its 5.0 mm unthreaded length and 30 mm case length define the bracket geometry.
The connected chain does not match this exact 90 option. This probe already has an integral 9.0 m lead for direct connection to the 9 m sensor, so the component order codes and system length need to be reconciled before the channel is energized.
The 148722-01 test plug provides a sensor-side check through the Proximitor Sensor test-pin holes without removing field wiring. This helps separate sensor behavior from the reverse-mount mechanical installation.
The route retains a 25.4 mm minimum bend radius and enough support to keep pull or repeated movement away from the probe case and connector. Reverse-mount probes are not available with an armored-lead option.
The delivered CSA, ATEX and IECEx markings need to agree with the project documentation and control drawing. Connector option 02 has no factory-installed protector, and the reverse-mount series has no protector ordering option.
The supplied product is covered for 12 months under ApterPLC's sales terms. Keep the product nameplate, original packaging and transaction record available if warranty support is required.
|
9200-06-02-10-00 |
128031-01C |
330101-00-08-10-02-00 |
|
330854-080-25-00 |
991-06-70-01-00 |
330101-00-08-20-02-05 |
|
10026-02-12-05-02 |
VELOMITOR 330500 |
330101-00-12-10-02-05 |
|
10030-05-30-05-02 |
130944-01 128275-01F |
330101-00-15-10-02-00 |
|
330104-00-12-10-02-05 |
330103-11-19-10-02-00 |
330101-00-16-10-02-00 |
|
330104-00-12-10-02-00 |
330103-00-07-10-02-00 |
330101-00-18-10-02-05 |
|
330104-00-14-05-02-00 |
330103-00-07-20-02-00 |
330101-00-19-10-02-00 |
|
330104-00-16-05-02-00 |
330103-00-08-05-02-00 |
330101-00-28-05-02-00 |
|
330104-00-17-05-02-00 |
330104-00-15-05-02-00 |
330101-00-30-10-02-05 |
|
330104-00-18-10-02-05 |
330103-00-08-10-02-00 |
330101-00-40-10-02-00 |
|
330103-12-25-10-01-00 |
330103-00-08-10-02-05 |
330101-00-50-10-02-00 |
|
330104-12-20-10-01-00 |
330103-00-09-10-02-00 |
330101-00-56-10-02-00 |
|
330104-00-24-05-02-00 |
330104-00-08-05-02-00 |
330101-00-60-10-02-00 |
|
330104-00-24-10-02-00 |
330103-00-08-05-02-CN |
330101-00-63-10-02-00 |
|
330703-000-050-10-02-05 |
330851-04-000-020-10-01-00 |
330101-00-12-10-01-CN |
Related Tags :