Short-lead system planning
- Calculate the extension cable from the 0.5 m probe length.
- Match the completed chain to the 5 m or 9 m Proximitor Sensor.
- Keep probe, cable and sensor within the same 3300 XL 8 mm family.
Item NO.:
330101-00-20-05-02-05Order(MOQ):
1Goods Stock:
10Payment:
T/TLead Time:
In stockWeight:
0.1KGDimension:
20x18x2cmDescription:
PROXIMITY PROBEPrice:
AskAn unarmored 3/8-24 UNF probe with a 2.0 in case, 0.5 m total length, standard ClickLoc connection without protector and CSA/ATEX/IECEx option.
Imperial-thread brackets for 330101-00-20-05-02-05 accommodate a 3/8-24 UNF forward-mount body, a 2.0 in case and an unarmored 0.5 m probe lead.
Connection planning for 330101-00-20-05-02-05 accounts for its option-02 ClickLoc joint without a protector, while option 05 provides CSA, ATEX and IECEx approvals.
System length is completed around 330101-00-20-05-02-05 with a 4.5 m extension cable for a 5.0 m chain or an 8.5 m extension cable for a 9.0 m chain.
The bracket needs a 3/8-24 UNF thread, clearance for the 2.0 in case and no more than 0.563 in of thread engagement. Machine geometry determines the sensing position and withdrawal space before the locknut is secured.
The 0.5 m probe pairs with a 4.5 m 3300 XL extension cable to form a 5.0 m system. A 9.0 m sensor instead uses an 8.5 m extension cable, keeping the probe, cable and sensor on one system-length basis.
The first useful comparison is the actual probe-plus-cable length against the connected 5.0 m or 9.0 m sensor. Correctly seated ClickLoc connectors and the physical probe gap then help separate a chain-length issue from a mechanical setup issue.
The order code is complete as supplied: option 02 specifies the standard ClickLoc connection without a protector. Environmental protection, when the site requires it, is a separate installation provision.
The +185 °C exposure exceeds the published +177 °C standard probe-and-cable limit. The route needs a lower-temperature location or a configuration whose published temperature capability covers the exposure; option 05 approval does not raise the temperature rating.
The 05 suffix identifies the CSA, ATEX and IECEx approval selection on the probe, but it does not approve a different completed installation. The product label, barrier or isolator, wiring and applicable control drawing need to agree before the loop is energized.
The supplied product is covered for 12 months under ApterPLC's sales terms. Keep the product nameplate, original packaging and transaction record available if warranty support is required.
|
9200-06-02-10-00 |
128031-01C |
330101-00-08-10-02-00 |
|
330854-080-25-00 |
991-06-70-01-00 |
330101-00-08-20-02-05 |
|
10026-02-12-05-02 |
VELOMITOR 330500 |
330101-00-12-10-02-05 |
|
10030-05-30-05-02 |
130944-01 128275-01F |
330101-00-15-10-02-00 |
|
330104-00-12-10-02-05 |
330103-11-19-10-02-00 |
330101-00-16-10-02-00 |
|
330104-00-12-10-02-00 |
330103-00-07-10-02-00 |
330101-00-18-10-02-05 |
|
330104-00-14-05-02-00 |
330103-00-07-20-02-00 |
330101-00-19-10-02-00 |
|
330104-00-16-05-02-00 |
330103-00-08-05-02-00 |
330101-00-28-05-02-00 |
|
330104-00-17-05-02-00 |
330104-00-15-05-02-00 |
330101-00-30-10-02-05 |
|
330104-00-18-10-02-05 |
330103-00-08-10-02-00 |
330101-00-40-10-02-00 |
|
330103-12-25-10-01-00 |
330103-00-08-10-02-05 |
330101-00-50-10-02-00 |
|
330104-12-20-10-01-00 |
330103-00-09-10-02-00 |
330101-00-56-10-02-00 |
|
330104-00-24-05-02-00 |
330104-00-08-05-02-00 |
330101-00-60-10-02-00 |
|
330104-00-24-10-02-00 |
330103-00-08-05-02-CN |
330101-00-63-10-02-00 |
|
330703-000-050-10-02-05 |
330851-04-000-020-10-01-00 |
330101-00-12-10-01-CN |
Related Tags :