Ethernet / RS232 I/O module
Item NO.:
136188-01Order(MOQ):
1Goods Stock:
26Payment:
T/TLead Time:
In stockWeight:
0.4KGDimension:
2.5x11.2x24.2cmDescription:
ETHERNET / RS232 MODBUS I/O MODULEPrice:
Ask
Provides Ethernet and RS232 connectivity for the 3500/92 Communication Gateway.
Bently Nevada 136188-01 belongs to the 3500/92 Communication Gateway. Provides Ethernet and RS232 connectivity for the 3500/92 Communication Gateway.
Ethernet / RS232 I/O module
Compatible gateway family
Ethernet interface
Serial Modbus interface
| Compatible system | 3500/92 Communication Gateway |
|---|---|
| Ethernet connector | RJ45 |
| Ethernet standard | 10BASE-T, 10 Mbps |
| Ethernet protocol | TCP/IP and Modbus/TCP |
| Serial interface | RS232 |
| Serial protocol | Modbus RTU |
| Rack position | One rear slot |
| Official module dimensions | 241 × 24.4 × 99.1 mm |
| Official module weight | 0.44 kg |
| Operating temperature | -30 to +65 °C |
| Storage temperature | -40 to +85 °C |
| Humidity | 95% non-condensing |
| Current backend stock | 26 |
| Current backend weight | 0.4KG |
| Current backend dimensions | 2.5x11.2x24.2cm |
| Place of shipment | Xiamen, China |
| Delivery Time | 1-3 days |
| Quantity | 100% New Original |
| Minimum Order Quantity | 1pc |
Capture the installed identity and mechanical context before disconnection.
Compare the exact family, length, mounting and connector details.
Review the receiving system, scale and commissioning response.
Include every order-code segment, manufacturer nameplate and approval marking.
Show the connected probe, cable, sensor, transmitter, rack module and receiving input as applicable.
Current backend stock, packed weight and dimensions remain unchanged until new warehouse evidence is supplied.
Confirm the fault is in the rear communications I/O path, then compare the installed part number, RJ45 and RS232 interfaces, rack position and the 3500/92 main-module identity.
Earlier 3500/92 main modules may require the manufacturer firmware upgrade kit supplied with this spare. Record the existing firmware level before replacement.
The module provides 10BASE-T Ethernet for TCP/IP and Modbus/TCP plus RS232 for Modbus RTU. Confirm which interface and protocol the plant system actually uses.
It occupies one rear rack slot associated with the 3500/92 gateway. Verify the paired front module and rear-slot location before disconnecting field cables.
Confirm the cabinet remains within -30 to +65 °C operating temperature and 95% non-condensing humidity, with adequate clearance for the 241 × 24.4 × 99.1 mm module.
Complete-label comparison before quotation.
Support for maintenance and project spares.
Quotation, delivery and after-sales communication.
Coverage begins on the shipment date unless the confirmed quotation states otherwise. Scope and available remedy follow the confirmed quotation and sales agreement.
Keep the product label and complete order reference.
Add connector or terminal photos and associated signal-chain labels.
Describe the observed symptom and operating context clearly.
Share a clear product label and the document type you need. ApterPLC will compare the request with the available manufacturer material and help identify the most relevant file.
Email: sales1@apterpower.comWhatsApp: +8618020776782Related Tags :